Product Description

IFD50W Long Range Electromagnetic Flow Meter
                                     
 
IFD50W series electromagnetic flowmeters is the advanced engineering designed magnetic flow meter;  It has a dual cavity housing isolating the electronics from the environment. It uses the low frequency excitation, which provides noise free output.
It is compliance with MODBUS RS485 protocol, it can realize the 2500 units to be one wireless net communication. It has strong power and can reach 10,000 meters.
 
Feature
1)No Moving Parts, mostly No Pressure Loss;
2)Corrosion protection, abrasion resistant;
3)High accuracy, Stable performance;
4) LCD display, wireless signal output
5) 433MHZ wireless communication,emission range is 6-10KM
Flow Meter Parameters
Power Supply24 VDC
Power Consumption10W
Accuracy± 0.5% accuracy of rate from 0.3-10 m/s
± 1.0% accuracy of rate from 0.1-0.3 m/s
Repeatability0.2%
Minimum Fluid Conductivity5.0 micromhos/cm
Flow DirectionUnidirectional or bidirectional, 2 separate totalizers (programmable)
Zero-point StabilityAutomatic correction
Ambient Temperature-4 to 140° F (-20 to 60° C)
Electrode MaterialsSS316L;
Optional: Titanium; Hastelloy Alloy C; Tantalum
Liner MaterialPTFE, FEP, Hard Rubber
Fluid TemperaturePTFE: 120°C Standard (Customized: 180°C)
Rubber: 60°C
Pressure Limits1.0 Mpa; Optional 1.6; 2.5; 4.0 Mpa
Coil PowerPulsed DC
Pipe Spool MaterialSS316
Meter Housing MaterialCarbon Steel welded or SS304 (Sanitary Connection)
FlangeCarbon Steel - Standard (ISO 7005-1)
ANSI, DIN and JIS Flange Connections
Optional Stainless Steel Grounding Rings
 
 
Wireless Part Parameters
 
Frequency Range119~1050MHz
Receiver Sensitivity-126dBm
Emission Power31dBm
Off Current30nA
Standby Current50 nA
Receiver Current10.0mA
Emission Current450mA
DATA Rate0.123~1M
Emission Range10000 Meter
In Condition(434M 2.4K)
Electric Connection

 
 
Accessory:
1, Electromagnetic sensor
2, Battery or Adapter
3, Receiver
4, PC software of Mobile phone App
 
 
 
 
Knowledge
How to choose the Lining materials 
Lining materialMain PerformanceApplications 
Teflon1.The most steady material in plastics which is resistibal to boiling hydrochloric 
acid,vitriolandqua fortis as well as strong alkali and organic impregnates.        
2.Not be perfect in abrasion resistance.
Strong corrosive mediums such 
as strong acid and alkali
 
PFAHaving the same abrasion resistance with PTFE.
Having strong ability of load pressure resistance.
Applicable in state of load pressure 
F461.Have the same abrasion resistance with PTFE.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.
  1.The same as PTFE.2.Applicable 
in mediums of low abrasion.
 
 Neoprene 1.Be of good elasticity,retractility and abrasion resistance.
2.Be resistant to low aicd,alkali and salt but not for oxidation mediums.
Water,sewage and slurry,mineral 
serosity of low abrasion.
 
Polyurethane1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resisitance.
3.Can't be used for water mixed with organic impregnants.
Applicable in mineral serosity,slurry 
and coal slurry of high abrasion.
 
How to choose the electrode materials
Electrode materialApplications
Stainless steel SUS316Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,
chemistry,carbamide,etc
Stainless steel
covered with tungsten carbide
Applicable in mediums of no corrosive and low abrasion.
  Hastelloy B(HB)Having strong resistance to hydrochloric acid of any consistance which is below bioling 
piont. Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which 
are oxidable  acid,alkali and non-oxidable salt.
Hastelloy C(HC)Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as
 Fe+++,Cu++and sea water
TitaniumApplicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid(including
fuming  nitric acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as 
sulphuric acid,hydrochloric acid)corrosion.But if acid contains antioxidant(such as 
Fe+++,Cu++)is greatly  reduce corrosion.
DaIn addition to hydrofluoric acid, fuming sulfuric acid, alkali remaining outside chemicals, 
including boiling hydrochloric acid
Platinum-iridiumAlmost be applicable in all chemical mediums except for aqua fortis,ammonium salt.
 
 
 
 
 
 
 
 
 
Order
 
IFD50WIPD50W Wireless Long Range Electromagnetic Flow Meter
 1433MHZ
 2ZigBee
 3GPRS
 4SMS
 5GPRS+SMS
 6Wi-Fi
 7Others
  DNxxxPipe Diameter xxx millimeter
    ATeflon Lining materials
    BPFA  Lining materials
    CF46  Lining materials
    DNeoprene  Lining materials
     Polyurethane  Lining materials
     1Stainless steel SUS316 Electrode Material
     2Stainless steel  covered with tungsten carbide  Electrode Material
covered with tungsten carbide
     3Hastelloy B(HB)  Electrode Material
     4Hastelloy C(HC)  Electrode Material
     5Titanium  Electrode Material
     6Da  Electrode Material
     7Platinum-iridium  Electrode Material
      AOuter Adapter Supply
      BInner Battery Supply
              YAccessories
              NNo
IFD50W1DN100---A1A       Y
            
 
 
 

Contact us if you need more details on Flow Sensor. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Water Flow Sensor、Wireless Flow Sensor. If these products fail to match your need, please contact us and we would like to provide relevant information.